undefined
+
  • undefined

Insulating rubber sheet

Insulating rubber sheets are manufactured from high-quality natural or synthetic rubber, compounded with specialized insulating additives and vulcanized at elevated temperatures, making them dedicated insulating protective materials for power and industrial applications. These products exhibit stable insulation performance, excellent compressive strength and wear resistance, slip resistance, and aging resistance, effectively blocking electric current and preventing electric shock accidents. They are suitable for a wide range of high- and low-voltage electrical work environments, available in a full range of standard specifications, and can be custom-cut to size.

Subclassification

hiddenValue

Contact Us


Add:yanling industrial zone, renqiu city, hebei province

  • Describe
  • Product Overview

    Insulating rubber mats are manufactured from high-quality natural or synthetic rubber, compounded with specialized insulating additives and vulcanized at elevated temperatures, making them dedicated insulating protective materials for power and industrial applications. The products exhibit stable insulation performance, excellent compressive strength and wear resistance, slip resistance, and aging resistance, effectively blocking electric current and preventing electric shock accidents. They are suitable for a wide range of high- and low-voltage electrical work environments, available in a full range of standard sizes and customizable cut-to-size options.

    Core Advantages

    1. Insulation performance meets standards, with multiple voltage ratings ranging from 5 kV to 35 kV available, ensuring reliable safety protection.
    2. The material is tough, highly elastic, and tear-resistant, making it resistant to deformation and cracking even after prolonged use.
    3. Oil- and stain-resistant, acid- and alkali-resistant, and aging-resistant; suitable for both indoor and outdoor environments.
    4. Anti-slip surface texture design enhances operational safety and facilitates easy installation.
    5. Available in multiple colors and specifications; custom sizes and thicknesses can be tailored to meet the needs of various applications.

    Product Basic Specifications

    - Width: 1 m / 1.2 m (customizable to 1.5 m)
    - Length: 5 m / 10 m per roll, can be cut to any desired length
    - Colors: black, red, green
    - Insulation rating: 5 kV / 10 kV / 15 kV / 20 kV / 25 kV / 30 kV / 35 kV

     

     

    Voltage-Thickness Standard Selection Comparison Table

    3 mm thick: withstands 6 kV
    5 mm thick: withstands 10 kV
    10 mm thick: withstands 35 kV

     

    Applicable Voltage Level Recommended Rubber Sheet Thickness Applicable Scenarios

    5 kV and below, 3 mm, for residential low-voltage systems, small distribution boxes, and simple control panels
    10 kV, 5 mm, standard distribution room, residential community distribution room, and mechanical and electrical maintenance workshop
    15 kV, 8 mm—around the factory distribution room and outdoor low-voltage switchgear cabinets
    20 kV, 10 mm substation auxiliary area and high-voltage switchgear operating area
    25kV 12mm High-Voltage Switchgear Room and Transformer Fixing Work Area
    30 kV, 15 mm high-voltage substation and outdoor high-voltage work site
    35kV 20mm UHV distribution room, high-voltage test bench, and specialized maintenance scenarios

    Instructions

    Paving Requirements

    1. Clean the floor before installation to ensure it is level, dry, free of sharp objects, oil stains, and standing water.
    2. Simply lay the tiles or panels directly; for large-area installations, ensure tight abutment with no lifting edges or hollow sounds.
    3. After installation, ensure the area is well-ventilated and dry to prevent prolonged water accumulation and soaking.

    Precautions

    1. Inspect the board surface before use; do not use if it is damaged, cracked, hardened, or blistered.
    2. Strictly prohibit puncturing with hard objects, dropping heavy objects on the surface, exposing to open flames, and contact with highly corrosive chemicals.
    3. Select equipment strictly according to voltage rating; the use of low-voltage panels in high-voltage environments is prohibited.
    4. Regularly wipe and clean with a neutral detergent to prevent degradation of insulation performance.
    5. To be used in conjunction with insulating shoes and insulating gloves; not to be used as a sole protective measure.

    Storage method

    Store rolled up in a cool, well-ventilated area, protected from light, heat, and pressure; keep away from chemicals; do not fold or crush.

    Applicable Scenarios

    Power and Electrical Scenarios

    Insulated protective measures for electrical maintenance and high-voltage operations in distribution rooms, substations, switchgear stations, high-voltage equipment rooms, around switchgear cabinets, and transformer areas.

    Industrial production scenarios

    Electromechanical workshop, electrical control console, equipment maintenance stations, and precision instrument room—designed for leakage protection, slip resistance, and vibration damping.

    Public Commercial Scenarios

    Daily safety protection for shopping malls, residential community distribution rooms, pump rooms, generator rooms, and property management distribution areas.
     
    New Energy Scenarios

    Outdoor insulation and slip resistance in areas surrounding electric vehicle charging stations, energy storage rooms, and new-energy equipment operation zones.

    Teaching and Practical Training Scenarios

    Dedicated to teaching and hands-on training: power training classroom, electrician practical examination venue, and vocational skills training base.

    Taboo Scenarios

    Do not use the product in high-temperature baking, strong acid or alkali soaking, continuous sharp friction, or intense radiation environments to prevent rapid damage, insulation failure, and potential safety hazards.